Below you will find charts to assist you in determining the distance between the camera and the part to be inspected.
We have indicated these charts for four camera models: HIK MV- CA023-10GC, BASLER acA1920-40gc, BASLER acA1920-48gc and BASLER acA2500-20gc and with a 12mm or 25mm lens.
Example of reading the charts:
- For a part to be inspected of size 70mm x 90mm (see the data in blue in the table)
- With a HIK MV-CA023-10GC Camera/12mm lens: minimum working distance of 100mm
- With a HIK MV-CA023-10GC Camera/25mm lens: minimum working distance of 250mm
- For a HIK MV-CA023-10GC camera with a 12mm lens and a working distance of 350 mm, the maximum viewing zone is (see the data in green in the table):
- 214.19mm wide and 340.89mm high
MV-CA023-10GC or acA1920-40gc camera /12mm lens
| Working distance (distance between the part and the camera) |
Field of view (width) |
Field of view (height) |
| 100 mm* |
66.27 mm* |
105.47 mm* |
| 150 mm |
95.85 mm |
152.55 mm |
| 200 mm |
125.44 mm |
199.64 mm |
| 250 mm |
155.02 mm |
246.72 mm |
| 300 mm |
184.6 mm |
293.8 mm |
| 350 mm* |
214.19 mm* |
340.89 mm* |
| 400 mm |
243.77 mm |
387.97 mm |
| 450 mm |
273.35 mm |
435.05 mm |
| 500 mm |
302.94 mm |
482.14 mm |
| 550 mm |
332.52 mm |
529.22 mm |
| 600 mm |
362.1 mm |
576.3 mm |
*The color refers to the example of reading the charts
MV-CA023-10GC or acA1920-40gc camera /25mm lens
| Working distance (distance between the part and the camera) |
Field of view (width) |
Field of view (height) |
| 100 mm |
35.5 mm |
56.5 mm |
| 150 mm |
49.7 mm |
79.1 mm |
| 200 mm |
63.9 mm |
101.7 mm |
| 250 mm* |
78.1 mm* |
124.3 mm* |
| 300 mm |
92.3 mm |
146.9 mm |
| 350 mm |
106.5 mm |
169.5 mm |
| 400 mm |
120.7 mm |
192.1 mm |
| 450 mm |
134.9 mm |
214.7 mm |
| 500 mm |
149.1 mm |
237.3 mm |
| 550 mm |
163.3 mm |
259.9 mm |
| 600 mm |
177.5 mm |
282.5 mm |
*The color refers to the example of reading the charts.
acA1920 48-gc camera/12mm lens
| Working distance (distance between the part and the camera) |
Field of view (width) |
Field of view (height) |
| 100 mm |
54.14 mm |
85.87 mm |
| 150 mm |
78.3 mm |
124.2 mm |
| 200 mm |
102.47 mm |
162.54 mm |
| 250 mm |
126.64 mm |
200.87 mm |
| 300 mm |
150.8 mm |
239.2 mm |
| 350 mm |
174.97 mm |
277.54 mm |
| 400 mm |
199.14 mm |
315.87 mm |
| 450 mm |
223.3 mm |
354.2 mm |
| 500 mm |
247.47 mm |
392.54 mm |
| 550 mm |
271.64 mm |
430.87 mm |
| 600 mm |
295.8 mm |
469.2 mm |
acA1920 48-gc camera/25mm lens
| Working distance (distance between the part and the camera) |
Field of view (width) |
Field of view (height) |
| 100 mm |
29 mm |
46 mm |
| 150 mm |
40.6 mm |
64.4 mm |
| 200 mm |
52.2 mm |
82.8 mm |
| 250 mm |
63.8 mm |
101.2 mm |
| 300 mm |
75.4 mm |
119.6 mm |
| 350 mm |
87 mm |
138 mm |
| 400 mm |
98.6 mm |
156.4 mm |
| 450 mm |
110.2 mm |
174.8 mm |
| 500 mm |
121.8 mm |
193.2 mm |
| 550 mm |
133.4 mm |
211.6 mm |
| 600 mm |
145 mm |
230 mm |
acA2500-20gc camera/12mm lens
| Working distance (distance between the part and the camera) |
Field of view (width) |
Field of view (height) |
| 100 mm |
91.47 mm |
115.74 mm |
| 150 mm |
132.3 mm |
167.4 mm |
| 200 mm |
173.14 mm |
219.07 mm |
| 250 mm |
213.97 mm |
270.74 mm |
| 300 mm |
254.8 mm |
322.4 mm |
| 350 mm |
295.64 mm |
374.07 mm |
| 400 mm |
336.47 mm |
425.74 mm |
| 450 mm |
377.3 mm |
477.4 mm |
| 500 mm |
418.14 mm |
529.07 mm |
| 550 mm |
458.97 mm |
580.74 mm |
| 600 mm |
499.8 mm |
632.4 mm |
acA2500-20gc camera/25mm lens
| Working distance (distance between the part and the camera) |
Field of view (width) |
Field of view (height) |
| 100 mm |
49 mm |
62 mm |
| 150 mm |
68.6 mm |
86.8 mm |
| 200 mm |
88.2 mm |
111.6 mm |
| 250 mm |
107.8 mm |
136.4 mm |
| 300 mm |
127.4 mm |
161.2 mm |
| 350 mm |
147 mm |
186 mm |
| 400 mm |
166.6 mm |
210.8 mm |
| 450 mm |
186.2 mm |
235.6 mm |
| 500 mm |
205.8 mm |
260.4 mm |
| 550 mm |
225.4 mm |
285.2 mm |
| 600 mm |
245 mm |
310 mm |